PF-075-095-ECO-LB

PF-075-095-ECO-LB

(Supercede® S6)
Nitrile Exam Gloves with EcoTek®

  • Comp CE 0493
  • Comp EN Food
  • Comp EN-374-1-and-EN374-5
  • SHA Approved-02

• Fully textured surface delivers added grip
• Beaded cuff allows easy donning and doffing
• 100% air inspected / consistent thickness tip to cuff
• EcoTek technology breaks down in landfills in less time

Description

This versatile powder-free 5.4 mil nitrile exam glove provides all the benefits of biodegradability without sacrificing safety or durability to deliver premium performance at the right price.

Features and Benefits

  • EcoTek® Biodegradability Technology accelerates landfill breakdown without any performance loss
  • Fully textured for excellent wet and dry grip
  • Powder-free to prevent contamination
  • Silicone-free for critical environments
  • Clean processing technology helps prevent skin irritation
  • Ambidextrous design simplifies inventory management
  • Tear-resistant beaded cuff eases donning
  • 1.5 AQL exceeds laboratory standards

Typical Applications

Assembly
Cleaning
Clinical
Handling & Packaging of Class I Medical Devices
Laboratory
Light Chemical Mixing
Liquid Handling
Oily or Wet Surfaces
Painting

Product Technologies

EcoTek

Yes

Specifications

Glove Type

Single-Use

Fit Type

Ambidextrous

Grade

Powder-Free Exam

Material

Nitrile

Finger Thickness mil

6.1mil

Finger Thickness mm

0.16mm

Palm Thickness mil

5.4mil

Palm Thickness mm

0.14mm

Cuff Thickness mil

4.0mil

Cuff Thickness mm

0.10mm

Color Outer

Light Blue

Surface Outer

Fully Textured

Length inch

9.5"

Length mm

242mm

Palm Width inch

4.3"

Palm Width mm

109mm

Weight in Grams

7.5g

Cuff Type

Beaded

AQL

1.5

Country Origin

China

Other

Silicone Free

Yes

Industries

Life Science

Yes

Healthcare

Yes

Industrial

Yes

Automotive After Market

Yes

Performance

Tensile Before

22 MPa

Tensile After

21 MPa

Elongation Before

590%

Elongation After

570%

Size Item Number UPC Number Packaging Unit
S (6 ½ - 7) N706312 0130616489506424 100/Bx 1000/Cs
M (7 ½ - 8) N706313 0130616489506431 100/Bx 1000/Cs
L (8 ½ - 9) N706314 0130616489506448 100/Bx 1000/Cs
XL (9 ½ - 10) N706315 0130616489506455 100/Bx 1000/Cs
2XL (10 ½ - 11) N706316 0130616489506462 100/Bx 1000/Cs

ANSI-ISEA-105 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 ANSI-ISEA 105 Level Report No.
Ammonia Solution 25% 7664-41-7 427 5 32603
Hydrofluoric Acid 10% 7664-84-1 480 6 9106
Hydrofluoric Acid 30% 7664-84-1 480 6 9106
Hydrogen Peroxide 30% 7722-84-1 467 5 32603
Isopropanol 57-63-0 353 5 32603
N-Heptane 142-85-5 91 3 32603
Sodium Hydroxide 40% 1310-73-2 480 6 32603
Sodium Hypochlorite 13% 7381-52-9 480 6 32603

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the ANSI-ISEA 105 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.

EN374-3 Chemical Permeation Breakthrough Times

Chemical CAS No. Breakthrough Time (BTT) Average (Minutes) ASTM F739-12 EN374-3 Level Report No.
Ammonia Solution 25% 7664-41-7 120 4 32603
Hydrofluoric Acid 10% 7664-84-1 480 6 9106
Hydrofluoric Acid 30% 7664-84-1 480 6 9106
Hydrogen Peroxide 30% 7722-84-1 240 5 32603
Isopropanol 57-63-0 120 4 32603
N-Heptane 142-85-5 30 2 32603
Sodium Hydroxide 40% 1310-73-2 480 6 32603
Sodium Hypochlorite 13% 7381-52-9 480 6 32603

The data provided is based on gloves tested by an accredited laboratory under conditions in accordance with ASTM F739-12 and reported according to the EN374-3 standard. Data is provided for guidance only and actual user results may vary due to conditions. User should always assess in advance the suitabiliity of gloves for use in specific applications. For more information, call us at +1.510.429.8692 or visit swsafety.com.

Product Technologies

Proprietary nitrile treatment that dramatically accelerates landfill breakdown. Gloves break down 92.6% over 2.5 years without any impact on glove performance.